WCT-0510

Chair Base Testing Machine

Product Specification

According to test Standard: BIFMA X5.1-2002, Test No. 5,6,8,10,11, 15,16, 18,22,23
Applicability:

This tester is designed to test office chairs.

Test No. 5 Backrest Strength Test – Static – Type I
Test No. 6 Backrest Strength Test – Static – Type II & III
Test No. 8 Drop Test – Dynamic
Test No.10 Tilt Mechanism Test – Cyclic
Test No.11 Seating Durability Test – Cyclic
Test No.13 Armrest Strength Test – Vertical
Test No.15 Backrest Durability Test – Cyclic – Type I
Test No.16 Backrest Durability Test – Cyclic – Type II & III
Test No. 18 Leg Strength Test – Front and Side
Test No. 22 Tablet Arm Static Load Test
Test No. 23 Tablet Arm Load Ease Test – Cyclic
Machine Mechanism:

  1. Testing force and frequency can be pre-set.
  2. Equipped with a protection cover.
  3. with displacement measurement function.
  4. The machine is operated via the corresponding POD(programmable operation display) system. One touch operation functions are easy for test. A test result will show as soon as the test is complete.
  5. Control system: adopt precision proportion valve via a pneumatic valve driver.
  6. Control mode: constant force, test time set, test frequency set.
  7. Control method: PLC + POD (programmable operation display)
  8. Selectable units of system – kg, N, lb.
  9. Test space: width: 1000mm, length: 1500mm

Safety protection:

  1. Maximum capacity pre-set: Once the pre-set level is reached, the machine stop autom-atically.
  2. Maximum displacement pre-set: Once the pre-set level is reached, the machine stop a-utomatically.
  3. Self monitoring of electric track closure, triggering automatic machine stoppage.
  4. Automatic detection of breakdown point while the test specimen breaks.
  5. Upper and lower limit with micro switch equipment: to protect machine mechanism, as incorrect use of this tester may result in property damage.
  6. Test report is printed once complete test.
  7. Conforms to national standard – Meets national standard requirement.

Note: Specifications are subject to change without notice.